Find Locations
For hours, walk-ins and appointments.Unable to load global navigation.
Find Locations
For hours, walk-ins and appointments.Alternaria alternata; Aspergillus fumigatus; Aureobasidium pullulans; Candida albicans; cat dander; chicken feathers; Cladosporium herbarum; cow dander; Dermatofagoides farinae; Dermatofagoides pteronyssinus; dog dander; duck feathers; goose feathers; mouse urine; Mucor racemosus; Penicillium chrysogenum; Phoma betae; Setomelanomma rostrata; Stemphylium herbarum
3 - 5 days
Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.
3 - |
3 - 5 days |
Serum
2 mL
Red-top tube or gel-barrier tube
Room temperature
Improper labeling; gross hemolysis
Detect possible allergic responses to various substances in the environment (see Test Includes) and evaluate for hay fever, asthma, atopic eczema, and respiratory allergy. The quantitative allergen-specific IgE test is indicated (1) to determine whether an individual has elevated allergen-specific IgE antibodies; (2) if specific allergic sensitivity is needed to allow immunotherapy to be initiated; (3) when testing individuals for agents that may potentially cause anaphylaxis; (4) when evaluating individuals who are taking medication (eg, long-acting antihistamines) that may interfere with other testing modalities (eg, skin testing); (5) if immunotherapy or other therapeutic measures based on skin testing results have not led to a satisfactory remission of symptoms; (6) when an individual is unresponsive to medical management where identification of offending allergens may be beneficial.
Thermo Fisher ImmunoCAP®
© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.
CPT Statement/Profile Statement
The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf