2019 Novel Coronavirus (COVID-19) With Respiratory Syncytial Virus, NAA

CPT: 87634; 87635
Print Share

Synonyms

  • 2019 Novel Coronavirus
  • COVID-19
  • Respiratory Viral panel
  • SARS-CoV-2

Special Instructions

Please note: Labcorp does not currently collect specimens for this test. Patients for whom testing has been ordered should not be sent to a Labcorp location to have a specimen collected. Instead, an appropriate specimen should be collected at the health care facility where the patient was seen and the test was ordered. The specimen should be sent to Labcorp using standard procedures.

Please note: It takes approximately 1 - 3 days from the date of pickup of a specimen for testing to the release of the test result to the health care provider. Test results are most typically reported electronically, which generally allows for faster delivery. This time frame can vary based on demand, the length of time to transport the specimen to Labcorp's test facilities, and the prioritization of the patients (as defined by heath care authorities and the White House Coronavirus Task Force, HHS and other health authorities). Labcorp is working continuously to support the needs of health care workers, patients, government, clients and other organizations, and expects capacity to continue to increase.

We have been regularly tracking mutations of the virus throughout the pandemic to determine the impact it would have on our test sensitivity. To date, we have not seen any impact.


Expected Turnaround Time

1 - 3 days


Related Documents


Specimen Requirements


Specimen

Anterior nasal swab; nasopharyngeal swab, mid-turbinate swab


Volume

1 - 3 mL


Minimum Volume

1 mL (Note: This volume does not allow for repeat testing.)


Container

Anterior nasal swab, nasopharyngeal (NP) swab or mid-turbinate swab in viral/universal transport medium (VTM/UTM) or 0.9% saline


Collection

Nasopharyngeal (NP) and mid-turbinate swabs: Collect using standard techniques. Place the swab into VTM/UTM and cap tightly.

Anterior nasal swab: Insert the tip of the swab into one nostril. The swab does not need to be inserted far. Insert just until the tip of the swab is no longer visible. Rotate the swab in a circle around the entire edge of your nostril at least three times. Repeat with the second nostril. Insert swab into the 0.9% saline tube and cap tightly.


Storage Instructions

Frozen at -20° C (preferred). Refrigerated specimens and room temperature specimens (if received for testing within 72 hours of collection) are also acceptable.


Stability Requirements

Temperature

Period

Room temperature

72 hours

Refrigerated

72 hours

Frozen

> 72 hours


Causes for Rejection

Unacceptable specimens include specimens that are beyond the established stability, improperly labeled, grossly contaminated, broken or with significant leakage in transit or improperly collected or shipped. Substances inhibitory to PCR should not be used to collect specimens; known inhibitory substances include heparin, hemoglobin, ethanol, EDTA concentrations > 0.01M. Specimens must be submitted with a swab.


Test Details


Use

Results are for the identification and differentiation of RNA from SARS-CoV-2 and RSV.


Limitations

This assay is intended for use only under the Food and Drug Administration's Emergency Use Authorization.


Methodology

Nucleic Acid Amplification (NAA)


LOINC® Map

Order Code Order Code Name Order Loinc Result Code Result Code Name UofM Result LOINC
140172 COVID-19 and RSV, NAA 78922-2 140141 SARS-CoV-2, NAA 94759-8
140172 COVID-19 and RSV, NAA 78922-2 140144 RSV, NAA 76089-2
140172 COVID-19 and RSV, NAA 78922-2 140177 Test Information: N/A
Reflex Table for SARS-CoV-2, NAA
Order Code Order Name Result Code Result Name UofM Result LOINC
Reflex 1 998900 SARS-CoV-2, NAA 2 DAY TAT 998900 SARS-CoV-2, NAA 2 DAY TAT N/A

For Providers

Please login to order a test

Order a Test

© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.

CPT Statement/Profile Statement

The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf