1 - 6 days
Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.
Serum
1 mL
0.5 mL (Note: This volume does not allow for repeat testing.)
Red-top tube or gel-barrier tube
Refrigerate
Temperature | Period |
---|---|
Room temperature | 14 days |
Refrigerated | 14 days |
Frozen | 14 days |
Freeze/thaw cycles | Stable x3 |
The detection of anti-HHV-6 IgM or a fourfold rise in anti-HHV-6 IgG supports a clinical diagnosis of HHV-6 infection. Human IgM antibodies to HHV-6 antigens are detected by indirect fluorescent antibody (IFA) assay. Diluted serum is incubated on a slide containing infected T-lymphoblasts. If specific HHV-6 antibodies are present, they remain bound, are then labeled by an antibody conjugate and finally detected by fluorescence microscopy.
Human Herpesvirus-6 (HHV-6) is a distinct herpes virus that typically causes a self-limiting illness in patients who are not immunocompromised. In some patients, especially if immunocompromised, HHV-6 can cause febrile convulsions in infants, encephalitis mononucleosis-like symptoms, and hepatitis.
IgM antibody only appears during an active infection or for 2-3 months after an active infection. However, the absence of an IgM antibody does not mean the patient does not have an active infection. Chronic infections in various tissues can persist with no evidence of IgM.
This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
Immunofluorescence (IF)
© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.
CPT Statement/Profile Statement
The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf